Elinca RX 600 User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
2
3
1
Mains fuse 8 AT
Modelling fuse 4 AF
Mains switch
(Only tempered)
Mains socket
4
Mains Supply
With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug
of the original ELINCHROM mains cord into the mains socket (1).
Mains Switch
The switch should light up when the compact is switched on ("I" position).
(Switch off before removing the mains cord).
Troubleshooting
If the on/off switch (3) is ON ("I" position) but not illuminated,
switch off the unit and check the mains fuse (2).
If failed replace with the correct fuse and switch ON the unit.
This unit is protected by a thermal circuit breaker to avoid overheating.
Should this occur, the unit turns off automatically and cannot be red.
After a break for cooling, the ash will be ready again for operation.
See page 10 / Troubleshooting
This equipment is not user serviceable and contains high voltages which are dangerous.
In the event of failure, please return the unit to an authorized Elinchrom service station.
Mains Fuse
Standard type 5 x 20 mm, (use only tempered fuse)
• Style 300RX : 5 AT
• Style 600RX : 6,3 AT
• Style 1200RX : 8 AT
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse
holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately upon reconnection, return
the unit to an ELINCHROM service centre for a check-up.
(N.B. Please don't forget to check the correct rating of the fuse !).
Fuse for modelling light
Fast type 5 x 20mm, 2.5 AF
Switch off the unit and replace the blown fuse with a new one of the correct rating.
The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore
the ash tube.
7
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments